Checklist
The following is a checklist for ensuring the quality of the frame members and the frame as a whole. Check each of the items listed below:
- walls for plumb, square, straight and level
- top and bottom plates have a tight fit on studs
- bracing and tie-downs in accordance with plan
- noggings at correct centres and support for fixtures
- corner blocking
- walls tied together
- room sizes and ceiling heights with plan
- window and door clearances and openings
- jamb studs to all openings
- concentrated load bearing studs
- lintels for adequate bearing
- block under studs if timber floor
- any excessive notching
- provisions for plumbing services and fixtures
- safety of frame
- adequacy of temporary bracing.